Battery Pack Data Properties

Friendly name (German) Attribute Example Value Data Type Description
Ladezustand socLevel 19% int Battery charge level
Gesundheitszustand soh 99,6% int State of Health
Status state Laden int 0: Standby, 1: Charging, 2: Discharging
Leistung power 34W int Battery pack power (charge/discharge direction depends on state)
Höchste Zelltemperatur maxTemp 21,0 C int Maximum battery temperature (maxTemp)
Gesamtspannung totalVol 49V int Total voltage
Höchste Zellspannung maxVol 3,25V int Maximum cell voltage, stored in units of 0.01V. The conversion formula to actual voltage: maxVol / 100.0 (Unit: V)
Niedrigste Zellspannung minVol 3,24V int Minimum cell voltage, stored in units of 0.01V. The conversion formula to actual voltage: minVol / 100.0 (Unit: V)
BMS Firmware softVersion v2.0.31 int Software version BMS

Read Only attributes

Friendly Name (German) Example Value Attribute Description
Akku entladen 0,09 kWh aggr_discharge_total daily amount discharged energy
Akku geladen 0,02 kWh aggr_charge_total daily amount charged energy
Ausgangsleistung 9 W output_home_power Output power to home electricity
Batterieanzahl 2 pack_num Number of battery packs
Batterie Ausgangsleistung 0 W pack_input_power Battery pack input power (discharging)
Batterie Eingangsleistung 58 W output_pack_power Output power to battery pack (charging)
Batterieladezustand 23 % electric_level Average battery pack charge level
blueOta 1 blue_ota ?
Bypass Aus pass "0": "Aus", "1": "An", "2": "Automatisch An"
Energieplan keiner auto_model "0": "Keiner", "6": "Akkuprioritätsmodus", "7": "Terminmodus", "8": "Intelligenter Abgleichmodus", "9": "Smart-CT-Modus", "10": "Strompreis"
Hardware Version not provided masterhaer_version ?
Hauptschalter Ein master_switch ?
Heizung Aus heat_state 0: Aus, 1: Ein
HEMS-Status Aus hems_state ?, SF1200 is Not Supported by hems
Hub-Status Output stoppen und ausschalten hub_state What happens if lower loading limit is reached; 1: Output stoppen und Abschalten (Stop and switch off; 0: Output stoppen und in Standby gehen (Stop and Standby
HubStatus Laden pack_state 1:Laden (Charge), 2:Entladen (Discharge), 0:Ruhezustand (Standby)
inputMode 0 input_mode ?
Master Firmware v2.0.48 master_soft_version Master Firmware Hub1200
Netzeingangsleistung 0 W grid_power ?
Online Aus wifi_state 1: Ein/On, 0:Aus/Off
smartMode 0 smart_mode ?
smartPower 0 smart_power ?
SOC Status 0 soc_status 0: No, 1: Calibrating, should be 0 in SF1200, there is no calibration mode
socLimit 0 soc_limit 0: Normal state, 1: Charge limit reached, 2: Discharge limit reached
Solar 128 W solar_input_power Total solar input power
Solar-Energie erzeugt 0,07 kWh aggr_solar_total daily amount of produced solar energy
solarPower1 23 W solar_power1 Solar line 1 input power
solarPower2 105 W solar_power2 Solar line 2 input power
switchCount 5 switch_count a sensor which detects a change between chargin, discharging and idle.
Verbindungsstatus Verbunden connection_status "0": "Unbekannt", "1": "Verbunden", "2": "HEMS", "3": "Keine Sicherungsgruppe"
Verbleibende Entladezeit 999 Std. remain_out_time Remaining discharge time (unit: minutes)
Verbleibende Ladezeit 999 Std. remain_input_time Remaining charge time (unit: minutes)
Verfügbare Energie 0,6 kWh available_kwh available capacity of batterie-stack
Wechselrichtereingang 700 W inverse_max_power Maximum output power limit
Wechselrichtermarke 3 pv_brand "1": "Hoymiles", "2": "Enphase", "3": "APsystems", "4": "Anker", "5": "Deye", "6": "BossWerk", "7": "TSun", "8": "Sonstige"

Device Data Properties - Read/Write

Friendly Name (German) Example Value Attribut Description
AC-Betriebsmodus AC-Ausgangsmodus ac_mode AC-Ausgangsmodus / AC Eingangsmodus (SF1200 only AC-Ausgang is releant)
Ausgangslimit 660 output_limit Maximum Output of Hub
Bestätigungston on buzzer_switch buzzer activated On/off
Bypass-Modus Automatisch pass_mode Automatisch, Immer An, Immer Aus
Bypass-Modus zurücksetzen Aus auto_recover AN/on, Aus/off: after switching off Bypass (pass_mode), this switch defines if the "automatic" Bypass mode should be reactivated next day
Eingangslimit 0 input_limit ?
Geräte-Sicherungsgruppe Sicherungsgruppe max. 800 W fuse_group "unused": "Nicht verwendet, Gerät hat keine Sicherungsgruppe", "owncircuit": "Gerät hat einen eigenen Stromkreis oder eine eigene Phase", "group800": "Sicherungsgruppe max. 800 W", "group1200": "Sicherungsgruppe max. 1200 W", "group2000": "Sicherungsgruppe max. 2000 W", "group2400": "Sicherungsgruppe max. 2400 W", "group3600": "Sicherungsgruppe max. 3600 W", a fuse group selection is necessary, if you would like to use the smart control function
Reset Verbindung mqtt_reset ?
SoC Maximum 100 soc_set Upper loading limit
SoC Minimum 16 min_soc Lower loading limit
Verbindungsart Cloud connection Cloud / Lokal