Operating a Device - ZGoode/Legacy_RS232_DripFeeder GitHub Wiki
Operating a Device
Discover and connect
- Place the device on a usable Ethernet or Wi-Fi network.
- Refresh FileLinkDiscovery and select a discovered device.
- Connect. The client requests device information, checks the discovered device ID, and evaluates password/setup state.
- The client performs best-effort local wall-clock time synchronization and reads SD status.
Time synchronization failure does not block the connection. The Connect workflow checks password state, but it is not evidence of a globally authorized session.
SD-card workflows
| Task | Confirmed behavior |
|---|---|
| Browse | Lists SD content through the device API. |
| Download | Requires a ready device CRC-cache value; writes to a temporary Windows file and finalizes only after CRC32 matches. |
| Upload | Windows calculates CRC32 before streaming; firmware validates the received data. |
| Delete | Deletes files or empty directories; directory deletion is not recursive. |
| Create directory | Creates one directory. |
| Format | Explicit action only; mount failure does not auto-format. |
Normal upload/download actions use an internal per-device transfer queue. The text editor transfers directly and bypass this queue.
Settings and reset
The settings UI provides device-name, password, RTC, Wi-Fi, Network Fallback, OTA, and factory-reset controls. Factory reset clears selected device settings, authentication state, and Wi-Fi credentials, then reboots. It does not erase SD contents.
RS232 (still lots of verification required here)