Data Dictionary: analyte units, names, and data source - USEPA/SuRGE GitHub Wiki

We need to adopt analyte names and reporting units that are consistent between the three analytical laboratories (MASI, ADA, AWBERC, daniels). I suggest that we adopt the analyte names and units shown in the table below. For example, the data frame would have a nh4 column and a nh4_units column. The value in nh4_units would be "ug_n_l".

Several inorganic nutrient analytes (no2, no2_3, oP) are quantified via ion chromatography and colorometric methods. The ion chromatography results are reported in the anion files and the colorometric results are reported in the nutrient files. We will always give preference to the colorometric results.

analyte units data source
site_depth m field measurement
ch4_diffusion_best mg ch4 m-2 h-1 Floating chamber, best fitting model
ch4_ebullition mg ch4 m-2 h-1 inverted funnel
ch4_total mg ch4 m-2 h-1 diffusion + ebullition
co2_diffusion_best mg co2 m-2 h-1 Floating chamber, best fitting model
co2_ebullition mg co2 m-2 h-1 inverted funnel
co2_total mg co2 m-2 h-1 diffusion + ebullition
n2o_ebullition mg n2o m-2 h-1 inverted funnel
nh4 ug_n_l colorometric
no2_3 ug_n_l colorometric
no3 ug_n_l colorometric
no2 ug_n_l colorometric
tn ug_n_l colorometric
tp ug_p_l colorometric
op ug_p_l colorometric
doc mg_c_l combustion, IR detection
toc mg_c_l combustion, IR detection
f mg_l ion chromotography
cl mg_l ion chromotography
br mg_l ion chromotography
so4 mg_l ion chromotography
al mg_l Inductively Coupled Plasma-Mass Spectrometry
as mg_l Inductively Coupled Plasma-Mass Spectrometry
ba mg_l Inductively Coupled Plasma-Mass Spectrometry
be mg_l Inductively Coupled Plasma-Mass Spectrometry
ca mg_l Inductively Coupled Plasma-Mass Spectrometry
cd mg_l Inductively Coupled Plasma-Mass Spectrometry
cr mg_l Inductively Coupled Plasma-Mass Spectrometry
cu mg_l Inductively Coupled Plasma-Mass Spectrometry
fe mg_l Inductively Coupled Plasma-Mass Spectrometry
k mg_l Inductively Coupled Plasma-Mass Spectrometry
li mg_l Inductively Coupled Plasma-Mass Spectrometry
mg mg_l Inductively Coupled Plasma-Mass Spectrometry
mn mg_l Inductively Coupled Plasma-Mass Spectrometry
na mg_l Inductively Coupled Plasma-Mass Spectrometry
ni mg_l Inductively Coupled Plasma-Mass Spectrometry
pb mg_l Inductively Coupled Plasma-Mass Spectrometry
p mg_l Inductively Coupled Plasma-Mass Spectrometry
sb mg_l Inductively Coupled Plasma-Mass Spectrometry
si mg_l Inductively Coupled Plasma-Mass Spectrometry
sn mg_l Inductively Coupled Plasma-Mass Spectrometry
sr mg_l Inductively Coupled Plasma-Mass Spectrometry
s mg_l Inductively Coupled Plasma-Mass Spectrometry
v mg_l Inductively Coupled Plasma-Mass Spectrometry
zn mg_l Inductively Coupled Plasma-Mass Spectrometry
microcystin ? ELISA
phycocyanin_lab ug_l fluorescence of phosphate buffer extraction
chla_lab ug_l fluorescence of acetone extraction
phycocyanin_sonde ug_l in situ fluorescence
chla_sonde ug_l in situ fluorescence
⚠️ **GitHub.com Fallback** ⚠️