1 |
Expected command letter |
G-code words consist of a letter and a value. Letter was not found. |
2 |
Bad number format |
Missing the expected G-code word value or numeric value format is not valid. |
3 |
Invalid statement |
Grbl '$' system command was not recognized or supported. |
4 |
Value < 0 |
Negative value received for an expected positive value. |
5 |
Setting disabled |
Homing cycle failure. Homing is not enabled via settings. |
6 |
Value < 3 usec |
Minimum step pulse time must be greater than 3usec. |
7 |
EEPROM read fail. Using defaults |
An EEPROM read failed. Auto-restoring affected EEPROM to default values. |
8 |
Not idle |
Grbl '$' command cannot be used unless Grbl is IDLE. Ensures smooth operation during a job. |
9 |
G-code lock |
G-code commands are locked out during alarm or jog state. |
10 |
Homing not enabled |
Soft limits cannot be enabled without homing also enabled. |
11 |
Line overflow |
Max characters per line exceeded. Received command line was not executed. |
12 |
Step rate > 30kHz |
Grbl '$' setting value cause the step rate to exceed the maximum supported. |
13 |
Check Door |
Safety door detected as opened and door state initiated. |
14 |
Line length exceeded |
Build info or startup line exceeded EEPROM line length limit. Line not stored. |
15 |
Travel exceeded |
Jog target exceeds machine travel. Jog command has been ignored. |
16 |
Invalid jog command |
Jog command has no '=' or contains prohibited g-code. |
17 |
Setting disabled |
Laser mode requires PWM output. |
18 |
No Homing/Cycle defined in settings |
Set some $homing/CycleX= Settings |
20 |
Unsupported command |
Unsupported or invalid g-code command found in block. |
21 |
Modal group violation |
More than one g-code command from same modal group found in block. |
22 |
Undefined feed rate |
Feed rate has not yet been set or is undefined. |
23 |
Invalid gcode ID:23 |
G-code command in block requires an integer value. |
24 |
Invalid gcode ID:24 |
More than one g-code command that requires axis words found in block. |
25 |
Invalid gcode ID:25 |
Repeated g-code word found in block. |
26 |
Invalid gcode ID:26 |
No axis words found in block for g-code command or current modal state which requires them. |
27 |
Invalid gcode ID:27 |
Line number value is invalid. |
28 |
Invalid gcode ID:28 |
G-code command is missing a required value word. |
29 |
Invalid gcode ID:29 |
G59.x work coordinate systems are not supported. |
30 |
Invalid gcode ID:30 |
G53 only allowed with G0 and G1 motion modes. |
31 |
Invalid gcode ID:31 |
Axis words found in block when no command or current modal state uses them. |
32 |
Invalid gcode ID:32 |
G2 and G3 arcs require at least one in-plane axis word. |
33 |
Invalid gcode ID:33 |
Motion command target is invalid. |
34 |
Invalid gcode ID:34 |
Arc radius value is invalid. |
35 |
Invalid gcode ID:35 |
G2 and G3 arcs require at least one in-plane offset word. |
36 |
Invalid gcode ID:36 |
Unused value words found in block. |
37 |
Invalid gcode ID:37 |
G43.1 dynamic tool length offset is not assigned to configured tool length axis. |
38 |
Invalid gcode ID:38 |
Tool number greater than max supported value. |
39 |
Parameter P exceeded max ID:39 |
Parameter P exceeded max |
60 |
SD mount |
SD card failed to mount |
61 |
SD reading |
SD card failed to open file for reading |
62 |
SD opening |
SD card failed to open directory |
63 |
SD diectory |
SD Card directory not found |
64 |
SD file |
SD Card file empty |
70 |
Bluetooth failed |
Bluetooth failed to start |