Core Configuration - SeriousOldMan/Simulator-Controller GitHub Wiki

All applications have been implemented on top of a specialized framework especially built for Simulator Controller. This framework itself provide a couple of configuration options, which can be tweaked to adapt the Simulator Controller applications to slower or even to very fast PCs. The standard configuration is good for a typical gaming PC setup from 2021, for example a Ryzen 5 3600 CPU with 32 GB RAM.

To change any of the low level configuration options, create a file named "Core Settings.ini" and place it in the Simulator Controller\Config folder which resides in your Documents folder. Then insert the options you want to change, but be sure to preceed them with the correct category header. Example:

[HTML]
Viewer=WebView2

Please note, that all this confguration options are documented here for the experienced user with technical skills. Do not change any of them, until you are told so by me, or you do know what you are doing.

Let's start with the configuration settings for the task processing engine. Four priority levels are defined and tasks with higher priority will postpone the processing of tasks with lower priority, when scheduled. For systems with a faster CPU you can make the schedule window smaller, whereas slower PCs might need a less demanding schedule plan.

Category Setting Default Description
Task Schedule.Interrupt 50 The number of milliseconds to wait between each schedule of tasks at interrupt level. Interrupt tasks are very important for the repsonsiveness of the user interface, but if the value is too low on a slower PC, tasks with lower priority might get no time at all. Example: Polling the Push-To-Talk button on the steering wheel is running at interrupt priority.
Schedule.High 200 The number of milliseconds to wait between each schedule of tasks with high priority. These tasks are very important stuff which can not wait until normal operations complete. Example: Detecting that one Assistant wants to issue an urgent notification to the driver thereby interrupting the speech of another Assistant.
Schedule.Normal 500 The number of milliseconds to wait between each schedule of tasks with normal priority. The majority of all internal tasks are running at this priority level. Example: Processing a message received by another proces.
Schedule.Low 2000 The number of milliseconds to wait between each schedule of tasks with low priority. All tasks that can wait until other processing has finihed are running at low priority. Example: The acquisition of telemetry data for the currently running session.

Built on top of the Task framework, the Message Manager handles the communcation between the different applications. The delivery of messages as well as the internal processing of a received message also have a schedule window.

Category Setting Default Description
Messages Schedule 200 The number of milliseconds to wait between each run of the message scheduler, which sends messages to and receives messages from other processes of Simulator Controller.
Dispatch 100 All received messages are placed in a queue for processing. This setting defines the number of milliseconds to let other activities run between each message processing.

The next group of settings are used mainly for development purposes. It allows to control the level of self-diagnosing of the framework during development and testing, but can also be used to track down really complex bugs in the production code. Please note, that some of these settings can also be toggled using the choices in the respective application menu during runtime.

Category Setting Default Description
Build Configuration Production Chooses the runtime mode (Production or Development) of the framework. This normaly determined during compile time, but it is possible to activate parts of the Development mode even for production code.
Debug Debug depending on configuration Specifies, whether the framework is running in a special debug mode. Default is false for a production (release) configuration and true for a development configuration. This option overwrites the choice as set in "Simulator Configuration" and it can be switched using the application menu.
LogLevel depending on configuration Defines the level of verbosity of the logging messages. Allowed values are Debug, Info, Warn, Critical and Off. Defult is Warn for production configuration and Debug for devlopment configuration. This option overwrites the choice as set in "Simulator Configuration" and it can be switched using the application menu.
LogStartup False If True, special logging is enabled which gives you insights into the timing during the startup process of any of the applications of Simulator Controller. Use this, if any of the applications seems to hang during startup.
Verbose depending on configuration Enables or disables additional and very verbose diagnostic output. Never use it in a real race, since error dialogs might popup while driving. Default is true for non-compiled code, when Debug is enabled, false otherwise.

The following group let's you control a couple of aspects of the voice recognition engine.

Category Setting Default Description
Voice Activation Recognizer Server Let's you choose the speech recognizer engine for the activation command used by the voice recognition. Allowed values here are: "Server", "Desktop" and "Azure|tokenIssuerEndpoint|subscriptionKey" (with tokenIssuerEndpoint and subscriptionKey substituted by their corresponding values.
Activation Speed 500 (Windows default) The maximum number of milliseconds between a click or press on the Push-To-Talk, so that an activation mode is triggered. Default is the Windows setting for the mouse double click speed (typically 500 ms, if not changed by the user).
High Rating 0.85 This value represents the Sorenson-Dice rating for a good enough match of a command phrase, when comparing a spoken command against the registered command syntax. The range of the rating is from 0.0 (no match at all) up to 1.0 (perfect word by word match). When a registered phrase is found with a High Rating quality index or higher, this command is used, regardless, whether there are remaining phrases to be tested. By tuning this setting, you can specify how precise the spoken commands must follow the registered syntax.
Low Rating 0.7 This value represents the Sorenson-Dice rating a registered command syntax must reach, when compared to a spoken command, so that this command is even considered. The range of the rating is from 0.0 (no match at all) up to 1.0 (perfect word by word match).

And finally a couple of other settings which configure low level components of Simulator Controller:

Category Setting Default Description
Controller External Dispatch 100 Specifies how long the central event loop waits in milliseconds before it checks again for external controller commands as described here.
HTML Viewer IE11 Many application uses and embedded HTML viewer to show graphs or other content. Actually there are two HTML engines available - IE11, which is based on the old Internet Explorer, which is out of support by Micorsoft and the new WebView2 engine, which is based on Chromium engine. Since the later uses quite some resources, IE11 is the default as long as it is available in Windows.
Simulator Data Provider DLL This defines the integration method used to acquire data from the different simulators. "EXE" is more reliable, but somewhat slower than "DLL", which is the default. If you encounter obviously wrong or missing data in race reports, for example, you can use the other method.
Stream Deck Protocol Message Specifies the communication method between Stream Deck and Simulator Controller. "Message", the default uses traditional message-based inter-process communication, whereas "File" writes the messages to a shared file. Use "File" only, if you encounter stability issues with message-based communication.
Team Server Update Frequency 10 Specifies the minimum number of seconds to wait between each update of the data acquired from the currently running simulator, when running a team session. This value (which you should only change by being told so), restricts the value set in the "Session Database" tool for the Data Update Frequency, so that the update frequency cannot get smaller in team sessions to protect the Team Server from update stalling.
Window ConstrainWindow True If True, windows will be constrained to a minimum size. If False, windows can be made smaller, but it may be possible that content may be made invisible in this case.