Temperature:
- Air Conditioner: conditions to turn on PID (or it's always on!) #1) If the outside air temperature is higher than the required temperature #2) If the required temperature is more than 3 degrees below the current temperature
- Heater: #1) If outside air temperature is lower than the required temperature #2) If the required temperature is more than 3 degrees above the current temperature Humidity:
- mister head: #1) Turn on mister and fan if the required humidity is greater than the outside humidity #2) Turn on mister and fan if the required humidity is more than 3% above current humidity #3) running on PID CO2:
- Exhaust Fan: #1) Turn on Exhaust fan if CO2 is greater than required CO2 levels. Oxygen (Respiration):
- Intake Fan: #1) Air intake is simply for respiration and to prevent an anaerobic situation. There is no need for a fast intake fan, the exhaust fan(s) is fast enough to clear the box from C02, and circulation is created by the 4 C-Fans. #3) If temp is within required temp range, intake air when exhausting C02, otherwise allow it to simply exhaust #4) breath mode for incubation and for fruiting