Jet Energy Resolution Validations of Pandora 06 09 16 - PandoraPFA/MarlinPandora GitHub Wiki

Validation of Pandora from 06-09-16


Reconstruction information used for validation:

  • ilcsoft v01-17-09.
  • 100 ns timing cut in the ECal and HCal.
  • Realistic digitsation in ILDCaloDigi.
  • Semi-infinite hadronic energy truncation.
  • Calibration done using PandoraAnalysis toolkit v01-02-01.
  • Pandora settings default used from ilcsoft v01-17-09.
Jet Energy / GeV Jet Energy Resolution [%] Jet Energy Resolution Error [%]
91 3.85623 0.0495571
200 3.10364 0.0397805
360 3.05934 0.038967
500 3.20173 0.0409102

Reconstruction information used for validation:

  • ilcsoft v01-17-09, but with master branches of PandoraPFA, MarlinPandora and PandoraAnalysis as of 06-09-16.
  • 100 ns timing cut in the ECal and HCal.
  • Realistic digitsation in ILDCaloDigi.
  • Semi-infinite hadronic energy truncation.
  • Calibration done using PandoraAnalysis toolkit v01-02-01.
  • Pandora settings default used from master branch of MarlinPandora as of 06-09-16.
Jet Energy / GeV Jet Energy Resolution [%] Jet Energy Resolution Error [%]
91 3.58861 0.0461178
200 2.79581 0.0358349
360 2.74938 0.0350189
500 2.83334 0.0362031

The degradation in performance in comparison to the master branch of 05 08 16 is due to the restriction on applying software compensation at energies above those which were used for training i.e. 100GeV in this case.