Bus Reactor Entity - POSOCO/wrldc_warehouse_data_migration_python GitHub Wiki

BUS_REACTOR

select ID, REACTOR_NO, FK_BUS, FK_SUBSTATION, MVAR_CAPACITY, DATETIME_OF_COMMISSIONING, DATETIME_OF_COD, DATETIME_OF_DECOMMISSIONING, LOCATION_ID, REACTOR_NAME from REPORTING_WEB_UI_UAT.BUS_REACTOR
  • FK_SUBSTATION is mapped to ID of ASSOCIATE_SUBSTATION
  • FK_BUS is mapped to ID of BUS
column type nullable
ID NUMBER(38,0) Yes
REACTOR_NO NUMBER(38,0) Yes
FK_BUS NUMBER(38,0) Yes
FK_SUBSTATION NUMBER(38,0) Yes
MAKE VARCHAR2(50 BYTE) Yes
MVAR_CAPACITY NUMBER(38,0) Yes
CONFIGURATION_1_PHASE_3_PHASE VARCHAR2(20 BYTE) Yes
SWITCHABLE_TYPE VARCHAR2(20 BYTE) Yes
NOMINAL_VOLTAGE_KV NUMBER(38,0) Yes
DATETIME_OF_FIRST_CHARGING TIMESTAMP(6) Yes
DATETIME_OF_FIRST_OPERATION TIMESTAMP(6) Yes
DATETIME_OF_COMMISSIONING TIMESTAMP(6) Yes
DATETIME_OF_COD TIMESTAMP(6) Yes
DATETIME_OF_DECOMMISSIONING TIMESTAMP(6) Yes
SWITCH_YARD_CONTACT_NUMBER NUMBER(38,0) Yes
DATA_AVAILABILITY_AT_RLDC VARCHAR2(20 BYTE) Yes
G_SHUNT_MW NUMBER(38,0) Yes
B_SHUNT_MVAR_B_SHUNT_MVAR NUMBER(38,0) Yes
G_ZERO_MW_G_ZERO_MW NUMBER(38,0) Yes
B_ZERO_MVAR_B_ZERO_MVAR NUMBER(38,0) Yes
DIFFERENTIAL_PROT_MAKE VARCHAR2(50 BYTE) Yes
DIFFERENTIAL_PROT_SETTING VARCHAR2(50 BYTE) Yes
REF_PROT_MAKE VARCHAR2(50 BYTE) Yes
REF_PROT_MODEL VARCHAR2(50 BYTE) Yes
REF_PROT_SETTING VARCHAR2(50 BYTE) Yes
OVER_FLUX_PROT_MAKE VARCHAR2(50 BYTE) Yes
OVER_FLUX_PROT_MODEL VARCHAR2(50 BYTE) Yes
OVER_FLUX_PROT_SETTING VARCHAR2(50 BYTE) Yes
BACK_UP_PROT_HV_SIDE_MAKE VARCHAR2(50 BYTE) Yes
BACK_UP_PROT_HV_SIDE_MODEL VARCHAR2(50 BYTE) Yes
BACK_UP_PROT_HV_SIDE_SETTING VARCHAR2(50 BYTE) Yes
REACTOR_BREAKER_LBB_PROT_MAKE VARCHAR2(50 BYTE) Yes
REACTOR_BREAKER_LBB_PROT_MODEL VARCHAR2(50 BYTE) Yes
REACTOR_BREAKER_LBB_PROT_SET VARCHAR2(50 BYTE) Yes
WTI_MAKE VARCHAR2(50 BYTE) Yes
WTI_MODEL VARCHAR2(50 BYTE) Yes
WTI_ALARM_SETTING CHAR(10 BYTE) Yes
WTI_TRIP_SETTING CHAR(10 BYTE) Yes
OTI_MAKE VARCHAR2(50 BYTE) Yes
OTI_MODEL VARCHAR2(50 BYTE) Yes
OTI_ALARM_SETTING NUMBER(38,0) Yes
OTI_TRIP_SETTING NUMBER(38,0) Yes
ADDITIONAL_PROT VARCHAR2(50 BYTE) Yes
PSSE_MAPPING_TRANSFORMER_ID NUMBER(38,0) Yes
PSSE_MAPPING_NAME VARCHAR2(50 BYTE) Yes
SE_SEM_METER_NO VARCHAR2(50 BYTE) Yes
SE_SEM_MAKE VARCHAR2(50 BYTE) Yes
SE_SEM_LOCATION_ID NUMBER(38,0) Yes
SE_SEM_FEEDER_NAME VARCHAR2(50 BYTE) Yes
SE_SEM_CT_RATIO NUMBER(38,0) Yes
SE_SEM_PT_CVT_RATIO NUMBER(38,0) Yes
RE_SEM_METER_NO VARCHAR2(50 BYTE) Yes
RE_SEM_MAKE VARCHAR2(50 BYTE) Yes
RE_SEM_LOCATION_ID NUMBER(38,0) Yes
RE_SEM_FEEDER_NAME VARCHAR2(50 BYTE) Yes
RE_SEM_CT_RATIO NUMBER(38,0) Yes
RE_SEM_PT_CVT_RATIO NUMBER(38,0) Yes
SCADA_DATA_REPORTING_FLAG VARCHAR2(10 BYTE) Yes
CREATED_BY VARCHAR2(100 BYTE) Yes
CREATED_DATE TIMESTAMP(6) Yes
MODIFED_BY VARCHAR2(100 BYTE) Yes
MODIFED_DATE TIMESTAMP(6) Yes
LOCATION_ID NUMBER(38,0) Yes
REACTOR_NAME VARCHAR2(100 BYTE) Yes
ELEMENT_TYPE VARCHAR2(200 BYTE) Yes

Owners

Owners can be found at REPORTING_WEB_UI_UAT.ENTITY_ENTITY_RELN

SELECT ID, PARENT_ENTITY_ATTRIBUTE_ID, CHILD_ENTITY_ATTRIBUTE_ID from REPORTING_WEB_UI_UAT.ENTITY_ENTITY_RELN WHERE PARENT_ENTITY='BUS_REACTOR' and PARENT_ENTITY_ATTRIBUTE='Owner' and CHILD_ENTITY='OWNER' and CHILD_ENTITY_ATTRIBUTE='OwnerId'