Target and Mimosa position


At the moment no feedback for the target position is available, except the Webcam monitor (see instructions for the motor movement).

Target and Mimosa on beam, nominal position :

Target
5.2 cm on the ruler (MAX value 5.3 cm)

Mimosa
9.2-9.3 cm on the ruler (MAX value 9.5 cm)

Please now for the movement of the Target use the webcam feedback.

Here a picture in which both of the detectors are on beam. http://www.le.infn.it/padme/forWEB/TargetMimosaOnBeam.png

Here a picture in which both of the detectors are out of beam:


Target High Voltage and Low Voltage Values


The LV voltage must be under 5 V, with a current of max 0.2 A.
The HV voltage for this runs is at -250 V, with a current of few umA.


(old) In the section DCS, in the online monitor, a feedback of the position of Target and Mimosa online is available (MAX value is the MAX position before the mechanical stop (a screw).