1.6

1.6.30

1.6.29

1.6.28

1.6.27

1.6.26

1.6.25

1.6.24

  • Added Bruker HyStar HPLC-DAD converter for .sqlite files inside .d folders. OpenChrom#886
  • Fixed a crash when two parsers conflict in file endings. ChemClipse#2996
  • Fixed LC-MS and HPLC-DAD not exporting into one mzML. ChemClipse#2993
  • Fixed no progress bar showing when loading scan proxies. ChemClipse#2988
  • Fixed performance problems with LC-MS profile scans with many ions. ChemClipse#2985

1.6.23

1.6.22

  • Added the Advion UV/DAD .datx import converter.
  • Added option to select the position directive for identifier export. OpenChrom#874
  • Added a button to manually create a new mass spectrum library entry. ChemClipse#2964
  • Added support to merge selected mass spectra from the library list. ChemClipse#2962
  • Added a dialog to display the mass spectrum and let the user modify it. ChemClipse#2961
  • Added an option to show the flavor markers and enable to modify them. ChemClipse#2960
  • Added a library editor tab item to show and edit the column indices. ChemClipse#2959
  • Fixed a crash when opening a chromatogram with no explicit converter requested. ChemClipse#2958
  • Removed unnecessary operating calls for performance increase. ChemClipse#2957

1.6.21

1.6.20

  • Fix typo in preference page and adjust menu icon package name. OpenChrom#872
  • Validate new assigner references on internal standard and identifier. OpenChrom#871
  • Prevent that the dialog is closed if ok is pressed in search text field. ChemClipse#2949
  • Dynamically edit the ComboSettingsProperty, by default edit=false ChemClipse#2948
  • Add proposals to the StringSettingsProperty to enable auto complete. ChemClipse#2947
  • Add support for indexed MzML ChemClipse#2946
  • Ensure that high/low pass peaks filter option '0' deletes all peaks. ChemClipse#2945
  • Do not fail on password protected zips ChemClipse#2944
  • Fix SWT Resource was not properly disposed exception. ChemClipse#2943
  • Reset perspective on e4 model ChemClipse#2942
  • Add Sample Name, Operator, Instrument and Tags as file name placeholder. ChemClipse#2941
  • Document the data explorer icons ChemClipse#2940
  • Fix delete targets not updating properly ChemClipse#2939
  • Harmonize compression support and add experimental slicer support. SWTChart#596
  • Add experimental fast Bresenham line series drawing algorithm option. SWTChart#595

1.6.19

1.6.18

1.6.17

1.6.16

1.6.15

1.6.14

1.6.13

1.6.12

1.6.11

1.6.10 (Analytica Edition)

1.6.9

1.6.8

1.6.7

  • Fixed a crash in reports that contain scan ranges. ChemClipse#2746
  • Fixed Area % not reporting sample name when it said so. ChemClipse#2743
  • Fixed performance after deleting multiple peaks in Peak/Scan list. ChemClipse#2741
  • Fixed unknown marker sharing its settings with copy to clipboard. ChemClipse#2740
  • Fixed file identifier always reporting zero matches in Feedback tab. ChemClipse#2738

1.6.6

  • Added back an option to avoid 🟥 red fill of rectangular selection in charts. SWTChart#562
  • Added dynamic settings to the scan identifier toolbar icons. ChemClipse#2731
  • Added ☑️ settings to Data Explorer to work around performance problems with network drives. ChemClipse#2724
  • Added private repositories to the plug-in installer UI. OpenChrom#789
  • Fixed a crash in MALDI-ToF MS gel view. ChemClipse#2726
  • Fixed drag and drop related crash on Windows. ChemClipse#2721
  • Fixed themeing not loading all stylesheets. OpenChrom#787

1.6.5

  • Added an optional file path to the CSV report. OpenChrom#782
  • Added Bruker EVOQ (*.qqq) DART import converter.
  • Added MALDI-ToF MS mass spectra centroidization. ChemClipse#2704
  • Added a sortable Loadings Table per principal component. ChemClipse#2695
  • Added highlights of error residuals in PCA charts. ChemClipse#2686
  • Fixed scalable vector graphics being rendered too small. ChemClipse#2705
  • Fixed legacy peak filter IDs not being recognized by process methods. ChemClipse#2124
  • Fixed process quick access toolbar not showing plug-in contributed icons. ChemClipse#2701
  • Fixed unrelated tiles being choosable on the welcome screen. ChemClipse#2690
  • Fixed peaks imported from AMDIS not being marked as deconvoluted. ChemClipse#2688
  • Fixed unknown marker not mentioning the correct number of peaks. ChemClipse#2689
  • Fixed error messages about invalid peaks being too verbose. ChemClipse#2687
  • Fixed crashes in process methods user interface. ChemClipse#2684
  • Fixed a followup crash in referenced chromatogram selection. ChemClipse#2682
  • Fixed a crash when .ocm process methods were removed. ChemClipse#2680

1.6.4

1.6.3

  • Added more effective default values for MALDI-TOF MS Savitzky-Golay smoothing. ChemClipse#2667
  • Added a filter to nominalize an MSD chromatogram and its references. ChemClipse#2662
  • Added possibility to overlay multiple chromatograms in Chromatogram Peak Chart. ChemClipse#2656
  • Added a label for polarity to Scan Chart/Table and Targets. ChemClipse#2652
  • Fixed highlighting routines for PCA samples. ChemClipse#2665
  • Fixed PCA variable/feature highlighting. ChemClipse#2660
  • Fixed PCA views hidden in the background not updating when gaining focus again. ChemClipse#2653
  • Fixed a crash when analyzing segments from total scan signals. ChemClipse#2664
  • Fixed Data Explorer performance by reducing the number of file format checks again. ChemClipse#2663
  • Fixed failed peak creation logging too verbose messages. ChemClipse#2657
  • Fixed reading instruments from mzML files. ChemClipse#2655

1.6.2