OpenStack Faulty Device

References

Faulty device的产生

What are faulty devices?

os-brick module is mainly used to connect/disconnect the devices.

Interface connect_volume is used to discover the block devices of storage systems, disconnect_volume is for cleaning the block devices.

When the multipath tool on hosts cannot access the host path, it marks the device as faulty.

How are faulty devices generated?

The faulty devices show up under the race condition occurs between connect_volume and disconnect_volume.

Copied from Peter's blog.

如上的流程在非并发的情况下是表现正常的,host上的device都可以正常连接和清理。

但是,以上逻辑有个实现上的问题,当高并发情况下,会产生faulty device, 考虑以下执行顺序:

  1. 右边的disconnect_volume执行完毕,存储上LUN对应的device path(在/dev/disk/by-path下可以看到)和multipath descriptor(multipath -l可以看到)。
  2. 这个时候,connect_volume锁被释放,左边的connect_volume开始执行,而右边的terminate_connection还没有执行,也就是说,存储上还没有移除host访问LUN的权限,任何host上的scsi rescan还是会发现这个LUN的device。
  3. 接着,connect_volume按正常执行,iscsi rescan 和multipath rescan都相继执行,造成在步骤 1)中已经删除的device又重新被scan出来。
  4. 然后,右边的terminate_connection在存储上执行完成,移除了host对LUN的访问,最终就形成的所谓的faulty device,看到的multipath 输出如下(两个multipath descriptor都是faulty的):
    $ sudo multipath -ll
    
    3600601601290380036a00936cf13e711 dm-30 DGC,VRAID
    size=2.0G features='1 retain_attached_hw_handler' hwhandler='1 alua' wp=rw
    |-+- policy='round-robin 0' prio=0 status=active
    | `- 11:0:0:151 sdef 128:112 failed faulty running
    `-+- policy='round-robin 0' prio=0 status=enabled
    `- 12:0:0:151 sdeg 128:128 failed faulty running
    
    3600601601bd032007c097518e96ae411 dm-2 DGC,VRAID
    size=1.0G features='1 queue_if_no_path' hwhandler='1 alua' wp=rw
    |-+- policy='round-robin 0' prio=0 status=active
    `- #:#:#:# -   #:#   active faulty running
    

The problem was that in connect_volume and disconnect_volume os-brick used multipath -r and iscsiadm -m session -R to rescan all the LUNs below to all iSCSI targets.

How does os-brick avoid to re-scan all LUNs?

Currently os-brick narrows down the scan scope. It only re-scans the LUN of specified iSCIS target.

First let's recall the way of linux kernel locates a block device. The address of a SCSI block device contains 4 parts:

  1. SCSI adapter number - host (h).
  2. Channel number - bus (c).
  3. ID number - target (t).
  4. LUN ID - (l).

Example:

$ ls -l /sys/class/iscsi_host/host3/device/session1/
total 0
drwxr-xr-x 4 root root    0 Apr 21 21:54 connection1:0
drwxr-xr-x 3 root root    0 Apr 21 21:54 iscsi_session
drwxr-xr-x 2 root root    0 Apr 21 21:55 power
drwxr-xr-x 5 root root    0 Apr 21 21:54 target3:0:0   <<< 3:0:0 is h:c:t
-rw-r--r-- 1 root root 4096 Apr 21 21:54 uevent

To rescan the specified LUN, os-brick cannot use multipath -r or iscsiadm -m session -R to rescan all the LUNs any more. It uses something like echo '0 0 1' | tee -a /sys/class/scsi_host/host3/scan to scan the specified channel - 0, target - 0, lun - 1.