Vibration - Moosevellous/Trace GitHub Wiki

Go to...
Convert Units
dB to Linear
Linear to dB
Accel/Vel/Disp Convert
Rating Curves
ASHRAE
AS2670
Building Vibration
Coupling Loss
Building Amplification

Convert Units

dB to Linear

Converts logarithmic (dB) units to linear units (mm/s) according to the equation:

v = "=" & v0*10^(dB/20)

Set to convert the row above the selected row by default.

[Back to top]

Linear to dB

Converts linear units (mm/s) to logarithmic (dB) units according to the equation:

dB=20*log(v/vref)

Set to convert the row above the selected row by default.

[Back to top]

Accel/Vel/Disp Convert

Conversion between displacement, velocity, and acceleration means multiplying or dividing by 2pif the correct number of times. Inserts the multiplier at each frequency band and optionally applies styles.

frmVibConvert.JPG

[Back to top]

Rating Curves

ASHRAE

TBD

[Back to top]

AS2670

Inserts the vibration criterion curves from AS2670 Evaluation of human exposure to whole-body vibration, in either linear or dB units, along with a multiplier.

frmAS2670.JPG

The reference curves from the standard are as follows, in one-third octave bands:

Accel/Vel (mm/s, mm/s^2) Axis 1 1.25 1.6 2 2.5 3.15 4 5 6.3 8 10 12.5 16 20 25 31.5 40 50 63 80
Accel z 0.010 0.009 0.008 0.007 0.006 0.006 0.005 0.005 0.005 0.005 0.006 0.008 0.010 0.013 0.016 0.020 0.025 0.031 0.039 0.050
Accel xy 0.004 0.004 0.004 0.004 0.005 0.006 0.007 0.009 0.011 0.014 0.018 0.023 0.029 0.036 0.045 0.057 0.072 0.090 0.114 0.144
Accel comb. 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0.005 0.005 0.006 0.008 0.010 0.013 0.016 0.020 0.025 0.031 0.039 0.050
Velocity z 0.0016 0.0011 0.0008 0.0006 0.0004 0.0003 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001
Velocity xy 0.0006 0.0005 0.0004 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003
Velocity comb. 0.0006 0.0005 0.0004 0.0003 0.0002 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001

[Back to top]

Building Vibration

Coupling Loss

Inserts the dB of Coupling Loss for the following building types:

  • Large Masonry On Piles
  • Large Masonry on Spread Footings
  • 2-4 Storey Masonry on Spread Footings
  • 1-2 Storey Commercial
  • Single Residential

frmCouplingLoss.JPG

Coupling loss values have been obtained from Nelson and have been extrapolated to include frequency bands below 16Hz.

Values are taken from: Transportation Noise Reference Book, Nelson, P (1987)

[Back to top]

Building Amplification

Inserts the dB of Amplification due to:

  • Ground-borne Noise
  • Floor Vibration

frmBuildingAmplification.JPG

Values are taken from: ANC Guidelines - Measurement and Assessment of Ground-borne Noise & Vibration, Association of Noise Consultants (2001)

[Back to top]