Vibration - Moosevellous/Trace GitHub Wiki
Go to... |
---|
Convert Units dB to Linear Linear to dB Accel/Vel/Disp Convert |
Rating Curves ASHRAE AS2670 |
Building Vibration Coupling Loss Building Amplification |
Converts logarithmic (dB) units to linear units (mm/s) according to the equation:
v = "=" & v0*10^(dB/20)
Set to convert the row above the selected row by default.
Converts linear units (mm/s) to logarithmic (dB) units according to the equation:
dB=20*log(v/vref)
Set to convert the row above the selected row by default.
Conversion between displacement, velocity, and acceleration means multiplying or dividing by 2pif the correct number of times. Inserts the multiplier at each frequency band and optionally applies styles.
TBD
Inserts the vibration criterion curves from AS2670 Evaluation of human exposure to whole-body vibration, in either linear or dB units, along with a multiplier.
The reference curves from the standard are as follows, in one-third octave bands:
Accel/Vel (mm/s, mm/s^2) | Axis | 1 | 1.25 | 1.6 | 2 | 2.5 | 3.15 | 4 | 5 | 6.3 | 8 | 10 | 12.5 | 16 | 20 | 25 | 31.5 | 40 | 50 | 63 | 80 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Accel | z | 0.010 | 0.009 | 0.008 | 0.007 | 0.006 | 0.006 | 0.005 | 0.005 | 0.005 | 0.005 | 0.006 | 0.008 | 0.010 | 0.013 | 0.016 | 0.020 | 0.025 | 0.031 | 0.039 | 0.050 |
Accel | xy | 0.004 | 0.004 | 0.004 | 0.004 | 0.005 | 0.006 | 0.007 | 0.009 | 0.011 | 0.014 | 0.018 | 0.023 | 0.029 | 0.036 | 0.045 | 0.057 | 0.072 | 0.090 | 0.114 | 0.144 |
Accel | comb. | 0.004 | 0.004 | 0.004 | 0.004 | 0.004 | 0.004 | 0.004 | 0.004 | 0.005 | 0.005 | 0.006 | 0.008 | 0.010 | 0.013 | 0.016 | 0.020 | 0.025 | 0.031 | 0.039 | 0.050 |
Velocity | z | 0.0016 | 0.0011 | 0.0008 | 0.0006 | 0.0004 | 0.0003 | 0.0002 | 0.0002 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 |
Velocity | xy | 0.0006 | 0.0005 | 0.0004 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 | 0.0003 |
Velocity | comb. | 0.0006 | 0.0005 | 0.0004 | 0.0003 | 0.0002 | 0.0002 | 0.0002 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 | 0.0001 |
Inserts the dB of Coupling Loss for the following building types:
- Large Masonry On Piles
- Large Masonry on Spread Footings
- 2-4 Storey Masonry on Spread Footings
- 1-2 Storey Commercial
- Single Residential
Coupling loss values have been obtained from Nelson and have been extrapolated to include frequency bands below 16Hz.
Values are taken from: Transportation Noise Reference Book, Nelson, P (1987)
Inserts the dB of Amplification due to:
- Ground-borne Noise
- Floor Vibration
Values are taken from: ANC Guidelines - Measurement and Assessment of Ground-borne Noise & Vibration, Association of Noise Consultants (2001)