10/40GbE per port runs only in NO-FEC and Force mode (ignores user configuration)
10/40
-
-
+
Copper
Up to 3
35
10/40GbE per port runs only in NO-FEC and Force mode (ignores user configuration)
25
-
+
-
Optic
Up to 100
50
25GbE per port runs only in RS-FEC and Force mode (ignores user configuration). LR modules are supported only when the device supports RS-FEC with these modules
25
-
+
-
Copper
Up to 5
50
25GbE per port runs only in RS-FEC and Force mode (ignores user configuration). LR modules are supported only when the device supports RS-FEC with these modules
50
-
+
-
Optic
Up to 100
60
50GbE per port runs only in RS-FEC and Force mode (ignores user configuration)
50
-
+
-
Copper
Up to 5
60
50GbE per port runs only in RS-FEC and Force mode (ignores user configuration)
100
-
+
-
Optic
Up to 100
36
100GbE per port runs only in RS FEC and Force mode (ignores user configuration). LR4/BiDi/SWDM4 modules are supported only when the device supports RS-FEC with these modules
100
-
+
-
Optic
Up to 100
36
100GbE per port runs only in RS FEC and Force mode (ignores user configuration). LR4/BiDi/SWDM4 modules are supported only when the device supports RS-FEC with these modules
200
-
-
-
Optic
-
-
Currently not supported. New FW version which can be provided by Mellanox supports it.
200
-
-
-
Optic
-
-
Currently not supported. New FW version which can be provided by Mellanox supports it.
Known Issues
Category
Description
Network configuration
Order of operations: Network configuration should be done bottom-up, teardown should be done top-down
ACL
ACL key size: Rules that match on L2 fields and the complete IPv6 header cannot be specified
FW automatic upgrade
Spectrum-2 in-driver firmware upgrade is not supported. See manual instructions Firmware upgrade
Multicast snooping
MDB records mapped to the same multicast MAC will share the same MDB record in the device. Deleting such records from the bridge driver will result in the following error being printed to the kernel log: "Unable to remove port from MC DB"