Sometimes during SMP/e installing RECEIVE step can end with RC=12 and the following message:
GIM44013I SYSTEM ABENO E37 OCCURRED WITH A REASON CODE OF '00000004'x AFTER S
SMPPTS LIBRARY RAN OUT OF SPACE. THE LIBRARY IS NOT ELIGIBLE FOR RE
GIM48300S ** SYSMOD sysmod COULD NOT BE SAVED IN THE SMPPTS LIBRARY BECAUSE IT
GIM24801W NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE RECEIVE COMMAND.
GIM20501I RECEIVE PROCESSING IS COMPLETE. THZ HIGHEST RETURN CODE WAS 12.
GIM20502I SMP/E PROCESSING IS COMPLETE. THE HIGHEST RETURN COOE WAS 12
This happens because SMPPTS library ran out of space. So, you need to recreate it with grater space.
Step 1. Find out SMPPTS library name
Go to 3.4 (DSLIST utility) and select your CSI
Now you know SMPPTS library name
Step 2. Create new SMPPTS library
Use 3.2 option (Data Set utility)
Enter current SMPPTS name
Press Enter and you will see Data Set Information
Press F3 and then enter new name and select “A” for allocate option
You will see the same parameters for new library. You need to change Primary quantity and Secondary quantity to do they bigger.
Step 3. Copy members from the current library to the new library
Step 4. Rename libraries
Now, you have SMPPTS library with the same name but bigger space. So, RECEIVE should end with RC=0.