New HPOVUplinkSet - HewlettPackard/POSH-HPEOneView GitHub Wiki

HPE OneView 4.10 Library

New-HPOVUplinkSet

Create a new Uplink Set.

SYNTAX

New-HPOVUplinkSet [-InputObject] <Object> [-Name] <String> [-Type] <String> [-Networks] <Array> [-NativeEthNetwork] <Object> [-UplinkPorts] <Array> [-EthMode] <String> [-LacpTimer] <String> [-PrimaryPort] <String>[ [-Async] <SwitchParameter>][ [-ApplianceConnection] <Object>] [<CommonParameters>]
New-HPOVUplinkSet [-InputObject] <Object> [-Name] <String> [-Type] <String> [-Networks] <Array> [-UplinkPorts] <Array> [-fcUplinkSpeed] <String>[ [-EnableTrunking] <bool>][ [-Async] <SwitchParameter>][ [-ApplianceConnection] <Object>] [<CommonParameters>]

Detailed Description

Interconnect uplinks are grouped into an uplink set and managed as a unit, with an assigned set of one or more networks. The traffic carried over the uplinks is determined by the network assignment of the uplink set. Uplink sets can support either Ethernet or Fibre Channel networks. Depending on the type of the assigned networks, uplink sets can support both an automatic and a selective failover or distribution strategy. The uplink port state is monitored, which contributes to the overall reachability status of the assigned networks. For each port belonging to the uplink set, the assigned port speed can be monitored. Uplink Sets can be created for Logical Interconnect Groups or Logical Interconnects. When creating a new Uplink Set, either the Logical Interconnect Group or Logical Interconnect must exist. Please know that the UplinkPorts parameter syntax is different between HPE BladeSystem and HPE Synergy Virtual Connect.

Parameters

-ApplianceConnection <Object>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s). If Resource object is provided via Pipeline, the ApplianceConnection property of the object will be used.

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? false
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-Async <SwitchParameter>

Use this parameter to immediately return the async task. By default, the Cmdlet will wait for the task to complete.

Aliases None
Required? false
Position? named
Default value false
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-EnableTrunking <bool>

Applicable only for Fibre Channel uplinks from the Virtual Connect Fibre Channel 16Gb or newer modules. The adjacent fibre channel switch must be a Brocade switch.

Aliases None
Required? false
Position? named
Default value false
Accept pipeline input? false
Accept wildcard characters?    False

-EthMode <String>

Aliases [-usEthMode] Sets the LACP mode on the uplink ports. Valid for ETHERNET Uplinks only. Accepted Values:

* Auto (Default)
* Failover
Aliases usEthMode
Required? true
Position? named
Default value Auto
Accept pipeline input? false
Accept wildcard characters?    False

-InputObject <Object>

Aliases [-li, -lig] Either a Logical Interconnect Group (Get-HPOVLogicalInterconnectGroup) or Logical Interconnect (Get-HPOVLogicalInterconnect) resource object.

Aliases li, lig, ligName, Resource
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-LacpTimer <String>

Set the LACP Timer value, which sets the lacpdu frequecy to the LACP peer. Accepted values:

* Long
* Short (Default)
Aliases None
Required? true
Position? named
Default value Short
Accept pipeline input? false
Accept wildcard characters?    False

-Name <String>

Aliases [-usName] Logical Uplink set Name

Aliases usName
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-NativeEthNetwork <Object>

Aliases [-usNativeEthNetwork, -Native, -PVID] The valid name of the Native Ethernet Network that is a member of the usNetworks parameter.

Aliases usNativeEthNetwork, Native, PVID
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Networks <Array>

Aliases [-usNetworks] Array of Ethernet Network Names

Aliases usNetworks
Required? true
Position? named
Default value @()
Accept pipeline input? false
Accept wildcard characters?    False

-PrimaryPort <String>

Specify the Primary Uplink Port when EthMode is set to Failover. Parameter is not valid when EthMode parameter is set to Auto.

Example: "Bay1:X1"

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Type <String>

Aliases [-usType] Uplink set Type. Accepted values are

* Ethernet (Default)
* FibreChannel
* Tunnel
* Untagged
* ImageStreamer

ImageStreamer is only supported with Synergy infrastructure. When assigning an Ethernet Network to an ImageStreamer Uplink Set, the network resource must be a Tagged Ethernet Network.

Aliases usType
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-UplinkPorts <Array>

Aliases [-usUplinkPorts] Array of uplink ports with "BAYID:FacePlatePortID". When configuring a Synergy infrastructure, the Uplink Port format needs to be "EnclosureID:BayID:FacePlatePortID".

FlexFabric e.g. @("BAY1:X1","BAY1:X2") or "BAY1:X5","BAY2:X5" VC Fibre Channel e.g. @("BAY3:1","BAY3:2") or "BAY3:1","BAY3:2" Synergy VC Ethernet e.g. "Enclosure1:Bay3:Q1","Enclosure1:Bay3:Q2","Enclosure2:Bay6:Q1","Enclosure2:Bay6:Q2" Synergy VC Sub-Interface e.g. "Enclosure1:Bay3:Q1.1","Enclosure1:Bay3:Q2.1","Enclosure2:Bay6:Q1.2","Enclosure2:Bay6:Q2.2" Synergy VC FC Primary Port e.g. "Bay2:Q1","Bay2:Q2" or "Bay5:Q1","Bay5:Q2" Synergy VC FC Sub-Interface e.g. "Bay2:Q1.1","Bay2:Q2.1" or "Bay5:Q1.2","Bay5:Q2.2"

Aliases usUplinkPorts
Required? true
Position? named
Default value @()
Accept pipeline input? false
Accept wildcard characters?    False

-fcUplinkSpeed <String>

Specify the Fibre Channel Uplink Port speed. Accepted values:

* Auto (Default)
* 2
* 4
* 8
Aliases None
Required? true
Position? named
Default value Auto
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

HPOneView.Networking.LogicalInterconnect [System.Management.Automation.PSCustomObject]

Logical Interconnect Resource from Get-HPOVLogicalInterconnect

HPOneView.Networking.LogicalInterconnectGroup [System.Management.Automation.PSCustomObject]

Logical Interconnect Group Resource from Get-HPOVLogicalInterconnectGroup

Return Values

HPOneView.Appliance.TaskResource {System.Management.Automation.PSCustomObject}

Async Task Resource object

Examples

 -------------------------- EXAMPLE 1 --------------------------

Get-HPOVLogicalInterconnectGroup -Name "LIG Prod" | New-HPOVUplinkSet -Name "Uplink Set 1" -Type Ethernet -Networks "RED","BLUE","GREEN" -NativeEthNetwork "RED" -UplinkPorts "BAY1:X5","BAY1:X6","BAY2:X5","BAY2:X6" -EthMode "Auto"

To Create an Ethernet Uplink Template

 -------------------------- EXAMPLE 2 --------------------------

$ethNets = "Net1","Net2","Net3" | Get-HPOVNetwork -Type Ethernet Get-HPOVLogicalInterconnectGroup -Name "LIG Prod" | New-HPOVUplinkSet -Name "Uplink Set 1" -Type Ethernet -Networks $ethNets -NativeEthNetwork $ethNets[0] -UplinkPorts "BAY1:X5","BAY1:X6","BAY2:X5","BAY2:X6" -EthMode "Auto"

Get the network resource objects, and define a new Uplink Set template that will be assigned to the Logical Interconnect Group resource.

 -------------------------- EXAMPLE 3 --------------------------

$LIGProd = Get-HPOVLogicalInterconnectGroup -Name "LIG Prod" New-HPOVUplinkSet -Resource $LIGProd -Name "Fabric A" -Type FibreChannel -Networks "FABRIC_A" -UplinkPorts "BAY1:X1","BAY1:X2"

To Create a Fibre Channel Uplink Template for VC FlexFabric modules.

 -------------------------- EXAMPLE 4 --------------------------

Get-HPOVLogicalInterconnect -Name "Encl1 LIG Prod" | New-HPOVUplinkSet -Name "New Uplink Set" -Type Ethernet -Networks "RED","BLUE","GREEN" -NativeEthNetwork "RED" -UplinkPorts "BAY1:X5","BAY1:X6","BAY2:X5","BAY2:X6" -EthMode "Auto"

Add a new Uplink Set to an existing Logical Interconnect resource.

 -------------------------- EXAMPLE 5 --------------------------

$MlagNetworks = Get-HPOVNetwork -Type Ethernet -Name "My MLAG Network*" Get-HPOVLogicalInterconnectGroup -Name "My Synergy Prod LIG" | New-HPOVUplinkSet -Name "MLAG UplinkSet" -Type Ethernet -Networks $MlagNetworks -NativeEthNetwork ($MlagNetworks | ? vlanid -eq 144) -UplinkPorts "Enclosure1:BAY3:Q1","Enclosure1:BAY3:Q2","Enclosure2:BAY6:Q1","Enclosure2:BAY6:Q2" -EthMode "Auto"

Create a Synergy MLAG Uplink Set using 40Gb capable ports.

 -------------------------- EXAMPLE 6 --------------------------

$MlagNetworks = Get-HPOVNetwork -Type Ethernet -Name "My MLAG Network*" Get-HPOVLogicalInterconnectGroup -Name "My Synergy Prod LIG" | New-HPOVUplinkSet -Name "MLAG UplinkSet" -Type Ethernet -Networks $MlagNetworks -NativeEthNetwork ($MlagNetworks | ? vlanid -eq 144) -UplinkPorts "Enclosure1:BAY3:Q1.1","Enclosure1:BAY3:Q2.1","Enclosure2:BAY6:Q1.1","Enclosure2:BAY6:Q2.1" -EthMode "Auto"

Create a Synergy MLAG Uplink Set using 10Gb subports of QSFP transceiver slots.

 -------------------------- EXAMPLE 7 --------------------------

$ImageStreamerDeploymentNetworkObject = Get-HPOVNetwork -Name "Deployment Network" -ErrorAction Stop Get-HPOVLogicalInterconnectGroup -Name "My Synergy VC+ImageStreamer LIG" -ErrorAction Stop | New-HPOVUplinkSet -Name "Image Streamer Uplink Set" -Type ImageStreamer -Networks $ImageStreamerDeploymentNetworkObject -UplinkPorts "Enclosure1:Bay3:Q3.1","Enclosure1:Bay3:Q4.1","Enclosure2:Bay6:Q3.1","Enclosure2:Bay6:Q4.1"

Create a Synergy ImageStreamer Uplink Set.

Related Links


Top

HPE OneView 4.00 Library

New-HPOVUplinkSet

Create a new Uplink Set.

SYNTAX

New-HPOVUplinkSet [-InputObject] <Object> [-Name] <String> [-Type] <String> [-Networks] <Array> [-NativeEthNetwork] <Object> [-UplinkPorts] <Array> [-EthMode] <String> [-LacpTimer] <String> [-PrimaryPort] <String>[ [-Async] <SwitchParameter>] [-ApplianceConnection] <Object> [<CommonParameters>]
New-HPOVUplinkSet [-InputObject] <Object> [-Name] <String> [-Type] <String> [-Networks] <Array> [-UplinkPorts] <Array> [-fcUplinkSpeed] <String>[ [-Async] <SwitchParameter>] [-ApplianceConnection] <Object> [<CommonParameters>]

Detailed Description

Interconnect uplinks are grouped into an uplink set and managed as a unit, with an assigned set of one or more networks. The traffic carried over the uplinks is determined by the network assignment of the uplink set. Uplink sets can support either Ethernet or Fibre Channel networks. Depending on the type of the assigned networks, uplink sets can support both an automatic and a selective failover or distribution strategy. The uplink port state is monitored, which contributes to the overall reachability status of the assigned networks. For each port belonging to the uplink set, the assigned port speed can be monitored. Uplink Sets can be created for Logical Interconnect Groups or Logical Interconnects. When creating a new Uplink Set, either the Logical Interconnect Group or Logical Interconnect must exist. Please know that the UplinkPorts parameter syntax is different between HPE BladeSystem and HPE Synergy Virtual Connect.

Parameters

-ApplianceConnection <Object>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s). If Resource object is provided via Pipeline, the ApplianceConnection property of the object will be used.

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? true
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-Async <SwitchParameter>

Use this parameter to immediately return the async task. By default, the Cmdlet will wait for the task to complete.

Aliases None
Required? false
Position? named
Default value false
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-EthMode <String>

Aliases [-usEthMode] Sets the LACP mode on the uplink ports. Valid for ETHERNET Uplinks only. Accepted Values:

* Auto (Default)
* Failover
Aliases usEthMode
Required? true
Position? named
Default value Auto
Accept pipeline input? false
Accept wildcard characters?    False

-InputObject <Object>

Aliases [-li, -lig] Either a Logical Interconnect Group (Get-HPOVLogicalInterconnectGroup) or Logical Interconnect (Get-HPOVLogicalInterconnect) resource object.

Aliases li, lig, ligName, Resource
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-LacpTimer <String>

Set the LACP Timer value, which sets the lacpdu frequecy to the LACP peer. Accepted values:

* Long 
* Short (Default)
Aliases None
Required? true
Position? named
Default value Short
Accept pipeline input? false
Accept wildcard characters?    False

-Name <String>

Aliases [-usName] Logical Uplink set Name

Aliases usName
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-NativeEthNetwork <Object>

Aliases [-usNativeEthNetwork, -Native, -PVID] The valid name of the Native Ethernet Network that is a member of the usNetworks parameter.

Aliases usNativeEthNetwork, Native, PVID
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Networks <Array>

Aliases [-usNetworks] Array of Ethernet Network Names

Aliases usNetworks
Required? true
Position? named
Default value @()
Accept pipeline input? false
Accept wildcard characters?    False

-PrimaryPort <String>

Specify the Primary Uplink Port when EthMode is set to Failover. Parameter is not valid when EthMode parameter is set to Auto.

Example: 'Bay1:X1'

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Type <String>

Aliases [-usType] Uplink set Type. Accepted values are

* Ethernet (Default)
* FibreChannel
* Tunnel
* Untagged
* ImageStreamer

ImageStreamer is only supported with Synergy infrastructure. When assigning an Ethernet Network to an ImageStreamer Uplink Set, the network resource must be a Tagged Ethernet Network.

Aliases usType
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-UplinkPorts <Array>

Aliases [-usUplinkPorts] Array of uplink ports with "BAYID:FacePlatePortID". When configuring a Synergy infrastructure, the Uplink Port format needs to be "EnclosureID:BayID:FacePlatePortID".

FlexFabric e.g. @("BAY1:X1","BAY1:X2") or "BAY1:X5","BAY2:X5" VC Fibre Channel e.g. @("BAY3:1","BAY3:2") or "BAY3:1","BAY3:2" Synergy VC Ethernet e.g. "Enclosure1:Bay3:Q1","Enclosure1:Bay3:Q2","Enclosure2:Bay6:Q1","Enclosure2:Bay6:Q2" Synergy VC Sub-Interface e.g. "Enclosure1:Bay3:Q1.1","Enclosure1:Bay3:Q2.1","Enclosure2:Bay6:Q1.2","Enclosure2:Bay6:Q2.2" Synergy VC FC Primary Port e.g. "Bay2:Q1","Bay2:Q2" or "Bay5:Q1","Bay5:Q2" Synergy VC FC Sub-Interface e.g. "Bay2:Q1.1","Bay2:Q2.1" or "Bay5:Q1.2","Bay5:Q2.2"

Aliases usUplinkPorts
Required? true
Position? named
Default value @()
Accept pipeline input? false
Accept wildcard characters?    False

-fcUplinkSpeed <String>

Specify the Fibre Channel Uplink Port speed. Accepted values:

* Auto (Default)
* 2
* 4
* 8
Aliases None
Required? true
Position? named
Default value Auto
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

HPOneView.Networking.LogicalInterconnect [System.Management.Automation.PSCustomObject]

Logical Interconnect Resource from Get-HPOVLogicalInterconnect

HPOneView.Networking.LogicalInterconnectGroup [System.Management.Automation.PSCustomObject]

Logical Interconnect Group Resource from Get-HPOVLogicalInterconnectGroup

Return Values

HPOneView.Appliance.TaskResource {System.Management.Automation.PSCustomObject}

Async Task Resource object

Examples

 -------------------------- EXAMPLE 1 --------------------------

Get-HPOVLogicalInterconnectGroup -Name 'LIG Prod' | New-HPOVUplinkSet -Name "Uplink Set 1" -Type Ethernet -Networks "RED","BLUE","GREEN" -NativeEthNetwork "RED" -UplinkPorts "BAY1:X5","BAY1:X6","BAY2:X5","BAY2:X6" -EthMode "Auto"

To Create an Ethernet Uplink Template

 -------------------------- EXAMPLE 2 --------------------------

$ethNets = 'Net1','Net2','Net3' | Get-HPOVNetwork -Type Ethernet Get-HPOVLogicalInterconnectGroup -Name 'LIG Prod' | New-HPOVUplinkSet -Name "Uplink Set 1" -Type Ethernet -Networks $ethNets -NativeEthNetwork $ethNets[0] -UplinkPorts "BAY1:X5","BAY1:X6","BAY2:X5","BAY2:X6" -EthMode "Auto"

Get the network resource objects, and define a new Uplink Set template that will be assigned to the Logical Interconnect Group resource.

 -------------------------- EXAMPLE 3 --------------------------

$LIGProd = Get-HPOVLogicalInterconnectGroup -Name 'LIG Prod' New-HPOVUplinkSet -Resource $LIGProd -Name "Fabric A" -Type FibreChannel -Networks "FABRIC_A" -UplinkPorts "BAY1:X1","BAY1:X2"

To Create a Fibre Channel Uplink Template for VC FlexFabric modules.

 -------------------------- EXAMPLE 4 --------------------------

Get-HPOVLogicalInterconnect -Name 'Encl1 LIG Prod' | New-HPOVUplinkSet -Name "New Uplink Set" -Type Ethernet -Networks "RED","BLUE","GREEN" -NativeEthNetwork "RED" -UplinkPorts "BAY1:X5","BAY1:X6","BAY2:X5","BAY2:X6" -EthMode "Auto"

Add a new Uplink Set to an existing Logical Interconnect resource.

 -------------------------- EXAMPLE 5 --------------------------

$MlagNetworks = Get-HPOVNetwork -Type Ethernet -Name 'My MLAG Network*' Get-HPOVLogicalInterconnectGroup -Name 'My Synergy Prod LIG' | New-HPOVUplinkSet -Name "MLAG UplinkSet" -Type Ethernet -Networks $MlagNetworks -NativeEthNetwork ($MlagNetworks | ? vlanid -eq 144) -UplinkPorts "Enclosure1:BAY3:Q1","Enclosure1:BAY3:Q2","Enclosure2:BAY6:Q1","Enclosure2:BAY6:Q2" -EthMode "Auto"

Create a Synergy MLAG Uplink Set using 40Gb capable ports.

 -------------------------- EXAMPLE 6 --------------------------

$MlagNetworks = Get-HPOVNetwork -Type Ethernet -Name 'My MLAG Network*' Get-HPOVLogicalInterconnectGroup -Name 'My Synergy Prod LIG' | New-HPOVUplinkSet -Name "MLAG UplinkSet" -Type Ethernet -Networks $MlagNetworks -NativeEthNetwork ($MlagNetworks | ? vlanid -eq 144) -UplinkPorts "Enclosure1:BAY3:Q1.1","Enclosure1:BAY3:Q2.1","Enclosure2:BAY6:Q1.1","Enclosure2:BAY6:Q2.1" -EthMode "Auto"

Create a Synergy MLAG Uplink Set using 10Gb subports of QSFP transceiver slots.

 -------------------------- EXAMPLE 7 --------------------------

$ImageStreamerDeploymentNetworkObject = Get-HPOVNetwork -Name 'Deployment Network' -ErrorAction Stop Get-HPOVLogicalInterconnectGroup -Name 'My Synergy VC+ImageStreamer LIG' -ErrorAction Stop | New-HPOVUplinkSet -Name 'Image Streamer Uplink Set' -Type ImageStreamer -Networks $ImageStreamerDeploymentNetworkObject -UplinkPorts "Enclosure1:Bay3:Q3.1","Enclosure1:Bay3:Q4.1","Enclosure2:Bay6:Q3.1","Enclosure2:Bay6:Q4.1"

Create a Synergy ImageStreamer Uplink Set.

Related Links


Top