Enable port monitoring for a logical interconnect.

SYNTAX

Enable-HPOVLogicalInterconnectPortMonitoring [-InputObject] <Object> [-AnalyzerPort] <Object> [-MonitoredPorts] <Hashtable>[ [-ApplianceConnection] <Array>] [<CommonParameters>]

Detailed Description

Port monitoring enables you to send a copy of every Ethernet or Fibre Channel frame coming in and going out of a downlink (server-facing) port to another port. To evaluate network traffic between ports, you can connect debugging equipment, such as a network analyzer. This capability is important in a server environment where there is limited physical access to the network interfaces on the servers.

NOTE: * You cannot use Virtual Connect to forward captured traffic to a server. For more information, see the HPE Virtual Connect for c-Class BladeSystem User Guide in the Hewlett Packard Enterprise Information Library. * You can configure one network analyzer port (the uplink port) for up to 16 downlink server ports within a logical interconnect. * The HPE Virtual Connect 16Gb 24-Port Fibre Channel Module monitors 1 downlink server port. * HPE Virtual Connect 16Gb 24-Port Fibre Channel Module firmware must be 4.00 or later

Required Privileges: Network administrator

Parameters

-AnalyzerPort <Object>

Specifies the network analyzer port (the mirrored-to uplink port) for the downlink server ports within a single enclosure. There is a single �mirrored-to port� per logical interconnect.

Allowed string value: "Bay1:X6" or "Enclosure1:Bay6:Q1.1"

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-ApplianceConnection <Array>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s).

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? False
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-InputObject <Object>

HPOneView.Networking.LogicalInterconnect from Get-HPOVLogicalInterconnect.

Aliases uri, li, name, Resource
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-MonitoredPorts <Hashtable>

An Array of Hashtable or PSCustomObject with the following format:

@{Port = "Bay1:D2"; Direction = "toserver"}

The "Port" property format must be "BayID:ServerDownlinkPortID". For HPE Synergy, the "Port" property must be "EnclosureID:BayID:ServerDownlinkPortID".

The "Direction" property value must be one of the following:

* ToServer
* FromServer
* Both
Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

HPoneView.Networking.LogicalInterconnect [System.Management.Automation.PSCustomObject]

Logical Interconnect resource object from Get-HPOVLogicalInterconnect

Return Values

HPOneView.Appliance.TaskResource [System.Management.Automation.PSCustomObject]

Asyncronous task resource to monitor.

Examples

 -------------------------- EXAMPLE 1 --------------------------

Get-HPOVLogicalInterconnect -Name "Encl1-Default VC FF LIG" | Enable-HPOVLogicalInterconnectPortMonitoring -AnalyzerPort "Bay1:Q1.1" -MonitoredPorts @{Port = "Bay1:d2"; Direction = "toserver"}, @{Port = "Bay1:D3"; Direction = "MonitoredFromServer"}, @{Port = "Bay2:D7"; Direction = "Both"}

Enable port monitoring for the specific logical interconnect.

 -------------------------- EXAMPLE 2 --------------------------

Get-HPOVLogicalInterconnect -Name "LE1-Default VC LIG" | Enable-HPOVLogicalInterconnectPortMonitoring -AnalyzerPort "Enclosure1:Bay3:Q1.1" -MonitoredPorts @{Port = "Enclosure1:Bay3:d1"; Direction = "Both"}, @{Port = "Enclosure1:Bay6:d1"; Direction = "Both"}

Enable port monitoring for the specific logical interconnect.

Related Links


Top

HPE OneView 4.00 Library

Enable-HPOVLogicalInterconnectPortMonitoring

Enable port monitoring for a logical interconnect.

SYNTAX

Enable-HPOVLogicalInterconnectPortMonitoring [-InputObject] <Object> [-AnalyzerPort] <Object> [-MonitoredPorts] <Hashtable>[ [-ApplianceConnection] <Array>] [<CommonParameters>]

Detailed Description

Port monitoring enables you to send a copy of every Ethernet or Fibre Channel frame coming in and going out of a downlink (server-facing) port to another port. To evaluate network traffic between ports, you can connect debugging equipment, such as a network analyzer. This capability is important in a server environment where there is limited physical access to the network interfaces on the servers.

NOTE: * You cannot use Virtual Connect to forward captured traffic to a server. For more information, see the HPE Virtual Connect for c-Class BladeSystem User Guide in the Hewlett Packard Enterprise Information Library. * You can configure one network analyzer port (the uplink port) for up to 16 downlink server ports within a logical interconnect. * The HPE Virtual Connect 16Gb 24-Port Fibre Channel Module monitors 1 downlink server port. * HPE Virtual Connect 16Gb 24-Port Fibre Channel Module firmware must be 4.00 or later

Required Privileges: Network administrator

Parameters

-AnalyzerPort <Object>

Specifies the network analyzer port (the mirrored-to uplink port) for the downlink server ports within a single enclosure. There is a single “mirrored-to port” per logical interconnect.

Allowed string value: "Bay1:X6" or "Enclosure1:Bay6:Q1.1"

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-ApplianceConnection <Array>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s).

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? False
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-InputObject <Object>

HPOneView.Networking.LogicalInterconnect from Get-HPOVLogicalInterconnect.

Aliases uri, li, name, Resource
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-MonitoredPorts <Hashtable>

An Array of Hashtable or PSCustomObject with the following format:

@{Port = "Bay1:D2"; Direction = "toserver"}

The "Port" property format must be "BayID:ServerDownlinkPortID". For HPE Synergy, the "Port" property must be "EnclosureID:BayID:ServerDownlinkPortID".

The "Direction" property value must be one of the following:

* ToServer
* FromServer
* Both
Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

HPoneView.Networking.LogicalInterconnect [System.Management.Automation.PSCustomObject]

Logical Interconnect resource object from Get-HPOVLogicalInterconnect

Return Values

HPOneView.Appliance.TaskResource [System.Management.Automation.PSCustomObject]

Async task Resource object for configuring port monitoring on the requested logical intercinnect.

Examples

 -------------------------- EXAMPLE 1 --------------------------

Get-HPOVLogicalInterconnect -Name "Encl1-Default VC FF LIG" | Enable-HPOVLogicalInterconnectPortMonitoring -AnalyzerPort 'Bay1:Q1.1' -MonitoredPorts @{Port = "Bay1:d2"; Direction = "toserver"}, @{Port = "Bay1:D3"; Direction = "MonitoredFromServer"}, @{Port = "Bay2:D7"; Direction = "Both"}

Enable port monitoring for the specific logical interconnect.

 -------------------------- EXAMPLE 2 --------------------------

Get-HPOVLogicalInterconnect -Name "LE1-Default VC LIG" | Enable-HPOVLogicalInterconnectPortMonitoring -AnalyzerPort 'Enclosure1:Bay3:Q1.1' -MonitoredPorts @{Port = "Enclosure1:Bay3:d1"; Direction = "Both"}, @{Port = "Enclosure1:Bay6:d1"; Direction = "Both"}

Enable port monitoring for the specific logical interconnect.

Related Links


Top
⚠️ **GitHub.com Fallback** ⚠️