Add HPOVResourceToRack - HewlettPackard/POSH-HPEOneView GitHub Wiki

HPE OneView 4.10 Library

Add-HPOVResourceToRack

Add supported resource to rack.

SYNTAX

Add-HPOVResourceToRack [-InputObject] <Object> [-Rack] <Object> [-ULocation] <Int32>[ [-ApplianceConnection] <Object>] [<CommonParameters>]

Detailed Description

Add a supported resource to a rack resource object.

Parameters

-ApplianceConnection <Object>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s).

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? false
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-InputObject <Object>

The suppported resource object from. Supported resource objects are: *Enclosures *Servers *Unmanaged Devices

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-Rack <Object>

The Rack object from Get-HPOVRack.

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-ULocation <Int32>

The rack unit location where the resource is located.

Aliases None
Required? True
Position? named
Default value 0
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

HPOneView.Facilities.Rack [System.Management.Automation.PSCustomObject]

Rack resource object from Get-HPOVRack.

Return Values

HPOneView.Facilities.Rack [System.Management.Automation.PSCustomObject]

Updated DataCenter object with the newly added Rack resource in the contents property.

Examples

 -------------------------- EXAMPLE 1 --------------------------

$Rack = Get-HPOVRack -Name MyRack221 -ErrorAction Stop $Servers = Get-HPOVServers -Name Prod221* -ErrorAction Stop $_U = 1 ForEach ($Server in $Servers) { Add-HPOVResourceToRack -InputObject $Server -Rack $Rack -ULocation $_U $_U += $Server.formFactor.Replace("U",$null) }

Add "Prod221" (DL) servers to "MyRack221" rack object, starting at Rack U 1, and increasing the location based on the form factor of the DL servers.

 -------------------------- EXAMPLE 2 --------------------------

$Rack = Get-HPOVRack -Name MyRack222 -ErrorAction Stop $Enclosures = Get-HPOVEnclosures -Name Encl-Prod* -ErrorAction Stop | ? rackName -eq $Rack.name $_U = 1 ForEach ($Enclosure in $Enclosures) { Add-HPOVResourceToRack -InputObject $Enclosure -Rack $Rack -ULocation $_U $_U += 10 }

Add Enclosures which the Onboard Administrators report are in "MyRack222", and add them to "MyRack222" rack object, starting at Rack U 1, and increasing the location by 10U.

Related Links


Top

HPE OneView 4.00 Library

Add-HPOVResourceToRack

Add supported resource to rack.

SYNTAX

Add-HPOVResourceToRack [-InputObject] <Object> [-Rack] <Object> [-ULocation] <Int32>[ [-ApplianceConnection] <Object>] [<CommonParameters>]

Detailed Description

Add a supported resource to a rack resource object.

Parameters

-ApplianceConnection <Object>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s).

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? false
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-InputObject <Object>

The suppported resource object from. Supported resource objects are: *Enclosures *Servers *Unmanaged Devices

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-Rack <Object>

The Rack object from Get-HPOVRack.

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-ULocation <Int32>

The rack unit location where the resource is located.

Aliases None
Required? True
Position? named
Default value 0
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

HPOneView.Facilities.Rack [System.Management.Automation.PSCustomObject]

Rack resource object from Get-HPOVRack.

Return Values

HPOneView.Facilities.Rack [System.Management.Automation.PSCustomObject]

Updated DataCenter object with the newly added Rack resource in the contents property.

Examples

 -------------------------- EXAMPLE 1 --------------------------

$Rack = Get-HPOVRack -Name MyRack221 -ErrorAction Stop $Servers = Get-HPOVServers -Name Prod221* -ErrorAction Stop $_U = 1 ForEach ($Server in $Servers) { Add-HPOVResourceToRack -InputObject $Server -Rack $Rack -ULocation $_U $_U += $Server.formFactor.Replace("U",$null) }

Add 'Prod221' (DL) servers to 'MyRack221' rack object, starting at Rack U 1, and increasing the location based on the form factor of the DL servers.

 -------------------------- EXAMPLE 2 --------------------------

$Rack = Get-HPOVRack -Name MyRack222 -ErrorAction Stop $Enclosures = Get-HPOVEnclosures -Name Encl-Prod* -ErrorAction Stop | ? rackName -eq $Rack.name $_U = 1 ForEach ($Enclosure in $Enclosures) { Add-HPOVResourceToRack -InputObject $Enclosure -Rack $Rack -ULocation $_U $_U += 10 }

Add Enclosures which the Onboard Administrators report are in 'MyRack222', and add them to 'MyRack222' rack object, starting at Rack U 1, and increasing the location by 10U.