Power on and boot the Datastorm DAQ with FMC card - ArrowElectronics/data-storm-daq GitHub Wiki
The DataStorm DAQ development kit is designed to run as a standalone desktop computer. Connect a keyboard, mouse and HDMI display to operate in this mode.

The following components are needed to Boot the DataStorm DAQ:
- Analog Devices [EVAL-AD400x-FMCZ] data converter board
- Trenz Intel® Cyclone® V SoC TEI0022 Development Board (includes 12VDC power supply)
- Signal Generator with dual outputs capable of channel tracking and inversion for differential outputs
- Two (2) [BNC to SMA] Cables
- Monitor with HDMI input
- HDMI cable
- Keyboard and Mouse with USB connectors
- Micro SD card
Select the SD card as the boot source for the processor.
The FMC_VADJ power rails provide power to the EVAL-ADRV9002NP/W1/PCBZ via the FMC interface. This is an adjustable voltage. It must be set to 3.3V. Modify the VID_SW DIP switch settings to select 3.3V.


Follow the steps in the order shown below.
- Insert the EVAL-AD400x-FMCZ FMC connector into the FMC mating connector on the Trenz TEI0022 board
- Insert the Micro SD card into the SD card slot.
- Attach the monitor to the TEI0022 using an HDMI cable
- Attach the keyboard and mouse to the TEI0022 using any of the 4 USB ports
- Connect the Signal Generator to the EVAL-AD400x-FMCZ SMA connectors
- Connect the power supply to the TEI0022
- Plug the AC-DC adapter into an AC outlet
Wait approximately 30 seconds for the DataStorm DAQ to boot.
The default desktop will appear on the HDMI display. The IIO Oscilloscope application will be automatically launched.