Install Required Hardware (AD7606B) - ArrowElectronics/data-storm-daq GitHub Wiki

Table of Contents

  1. Configuration for local IIO Oscilloscope access
  2. Configuration for remote IIO Oscilloscope access via ethernet

Configuration for local IIO Oscilloscope access



The DataStorm DAQ development kit is designed to run as a standalone desktop computer. Connect a keyboard, mouse and HDMI display to operate in this mode.

The AD7606B Evaluation Platform in this configuration is comprised of the following components:

  • Analog Devices EVAL-AD7606B-FMCZ data converter board
  • DataStorm DAQ (Trenz Intel® Cyclone® V SoC TEI0022 Development Board) (includes 12VDC power supply)
  • Signal Generator with dual outputs capable of channel tracking and inversion for differential outputs
  • one (1) BNC to SMA Cables
  • Monitor with HDMI input
  • HDMI cable
  • Keyboard and Mouse with USB connectors

Assemble the Hardware

Follow the steps in the order shown below.

  1. Insert the EVAL-AD7606B-FMCZ FMC connector into the FMC mating connector on the DataStorm DAQ board
  2. Attach the monitor to the DataStorm DAQ using an HDMI cable
  3. Attach the keyboard and mouse to the DataStorm DAQ using any of the 4 USB ports
  4. Connect the Signal Generator to the EVAL-AD7606B-FMCZ SMA connectors
  5. Connect the power supply to the DataStorm DAQ
  6. Plug the AC-DC adapter into an AC outlet

Configuration for remote IIO Oscilloscope access via ethernet

The AD7606B® Evaluation Platform in this configuration is comprised of the following components: The AD7606B Evaluation Platform in this configuration is comprised of the following components:

  • Analog Devices EVAL-AD7606B-FMCZ data converter board
  • DataStorm DAQ (Trenz Intel Cyclone V SoC TEI0022 Development Board) (includes 12VDC power supply)
  • Computer with IIO Oscilloscope installed
  • Ethernet Cable
  • Micro USB cable
  • Signal Generator with dual outputs capable of channel tracking and inversion for differential outputs
  • one (1) BNC to SMA Cables

Assemble the Hardware

Follow the steps in the order shown below.

  1. Insert the EVAL-AD7606B-FMCZ FMC connector into the FMC mating connector on the DataStorm DAQ board
  2. Attach PC via ethernet cable
  3. Attach the Micro USB cable to the micro-USB connector for UART access
  4. Connect the Signal Generator to the EVAL-AD7606B-FMCZ SMA connectors
  5. Connect the power supply to the DataStorm DAQ
  6. Plug the AC-DC adapter into an AC outlet




Next- Install Required Software

Return to AD7606B Quick Start Guide

⚠️ **GitHub.com Fallback** ⚠️