The DataStorm DAQ development kit is designed to run as a standalone desktop computer. Connect a keyboard, mouse and HDMI display to operate in this mode.
The AD469x demonstration uses AD4696® Evaluation Platform in this configuration which is comprised of the following components:
- Analog Devices EV-AD4696-FMCZ (also known as EVAL-AD4696-FMCZ) data converter board
- DataStorm DAQ (Trenz Intel® Cyclone® V SoC TEI0022 Development Board ) (includes 12VDC power supply)
- Digilent® Analog Discovery 2 Signal Generator with dual outputs
- Digilent Discovery BNC adapter board
- One (1) BNC Male to SMB Female Cable
- Monitor with HDMI input
- HDMI cable
- Keyboard and Mouse with USB connectors
- Separate Windows PC running Digilent WaveForms App
Follow the steps in the order shown below.
- Insert the Micro SD card into the SD card slot
- Insert the EVAL-AD469x-FMCZ FMC connector into the FMC mating connector on the DataStorm DAQ board
- Attach the monitor to the DataStorm DAQ using an HDMI cable
- Attach the keyboard and mouse to the DataStorm DAQ using any of the 4 USB ports
- Connect the Signal Generator to the EVAL-AD469x-FMCZ SMA connectors
- Ensure that Jumper JP11 is at position B to give onboard 5V reference, Jumper JP8 is in position A to give VADJ from FMC connector, Jumper JP7 is in position A to supply LDOin with AVDD.
- Connect the power supply to the DataStorm DAQ
- Plug the AC-DC adapter into an AC outlet

The AD469x demonstration uses AD4696® Evaluation Platform in this configuration which is comprised of the following components:
- Analog Devices EV-AD4696-FMCZ (also known as EVAL-AD4696-FMCZ) data converter board
- DataStorm DAQ (Trenz Intel Cyclone V SoC TEI0022 Development Board) (includes 12VDC power supply)
- Host Windows PC with IIO Oscilloscope and Digilent WaveForms App installed
- Ethernet Cable
- Micro USB cable
- Digilent Analog Discovery 2 Signal Generator with dual outputs
- Digilent Discovery BNC adapter board
- one (1) BNC male to SMB Female Cable
Follow the steps in the order shown below.
- Insert the Micro SD card into the SD card slot
- Insert the EVAL-AD469x-FMCZ FMC connector into the FMC mating connector on the DataStorm DAQ board
- Attach PC via ethernet cable
- Attach the Micro USB cable
- Connect the Signal Generator to the EVAL-AD469x-FMCZ SMA connectors (channel 0)
- Ensure that Jumper JP11 is at position B to give onboard 5V reference, Jumper JP8 is in position A to give VADJ from FMC connector, Jumper JP7 is in position A to supply LDOin with AVDD.
- Connect the power supply to the DataStorm DAQ
- Plug the AC-DC adapter into an AC outlet