DAQ1_Demo - ArrowElectronics/AnalogMAX GitHub Wiki

Running the AnalogMAX-DAQ1, AnalogMAX-DAQ2, or AnalogMAX-DAQ3 demo

This demo is run within either the Jupyter Notebook (in your web browser) or within the DAQCapture Windows Application. It is designed with the focus of capturing signals. Therefore the module works like a storage oscilloscope. After a trigger event, the module saves 1 million samples of ADC measurement in its SDRAM.

The demo scans for existing comports in its initialisation phase. So the module needs to be connected to the computer prior to running the demo.

Now supply a signal to the inputs (via SMA jack or connector J8). Another option is to use the module's internal square wave signal output. Connect the digital outputs D5 and D6 to the input pins. Click the checkbox in the application to activate the internal square wave signal output. Be careful, do not short the outputs D5 or D6 to ground.

One can set up a pre-amplification gain of the input signal and the amount of samples to be processed.

Next Steps: