znt_score - theonesp/p_zero-code GitHub Wiki

Source table from the HIS containing vitals. Every instance is generated with every validation from the nurse in charge.

How a row of r_monitor table is generated:

Whenever any of the clinical records that are used to calculate the NEWS_2 are introduced, the system creates an register with all the variables that are in the system at that moment and tries to calculate the NEWS_2 score, but not always all the data have been completed, for example consciousness may be missing and thus only registers with all parameters contain the actual NEWS_2 score.

Once the news_2 has been determined, different actions that we have parameterized are made, in these fields we indicate the actions that have been carried out, pop-up is that in case that it has been registered manually, a pop-up warning has been shown at the bottom of the screen; envio_medxat_med, that a medxat has been sent to the doctor's pager; envio_medxat_enf, that a medxat has been sent to the nurse's pager; envio_email, that an email has been sent (this option is not currently used).

valors field contains all available vitals in a label:value format at that time point. Examples of labels: 'CONC_STATE', 'HR_ECG', 'RR_IP', 'PA_S', 'PULSIOX', 'TEMP_AXI', 'O2_SUPPORT', 'PRESN', 'SBP', ‘TEMP_AXI’, ‘TEMP_TIM’ OR TEMP_BU’ , ‘TEMP_CT’

item description
mandt
id_score This is the name of the score that is calculated on vwert field, currently we are only using NEWS_2.
data is the date when the score was determined in the HIS
hora is the time when the score was determined in the HIS
patnr patient record number
id random number assigned to every patient to anonimize patnr
usuari Is the user who has triggered the NEWS_2 calculation by entering one of the variables. If the user is WSBETTERCARE it means that it has been using a data capture equipment, either an ICU monitor or a mobile device.
vpid If all the required clinical records are present, the parameter NEWS_2 is calculated as a clinical record. In the vpid field is the ID of the created clinical record, which is linked to the VPID of the clinical records table.
vwert is the value of the news_2 score that has been determined at that moment if there's parameters enough to calculate it.
pop_up is that in case that it has been registered manually
envio_medxat_med that a medxat has been sent to the doctor's pager
envio_medxat_enf that a medxat has been sent to the nurse's pager
envio_email that an email has been sent (this option is not currently used).
valors field of monitor outputs: 'label': value
aillat mark that warns that a single clinic record already has a value too deviated to activate the rapid response equipment. for example a heart rate with a value of 150.
⚠️ **GitHub.com Fallback** ⚠️