Jet Energy Resolution Validations of Pandora 05 08 16 - PandoraPFA/MarlinPandora GitHub Wiki

Validation of Pandora from 05-08-16


Reconstruction information used for validation:

  • ilcsoft v01-17-09.
  • 100 ns timing cut in the ECal and HCal.
  • Realistic digitsation in ILDCaloDigi.
  • Semi-infinite hadronic energy truncation.
  • Calibration done using PandoraAnalysis toolkit v01-02-01.
  • Pandora settings default used from ilcsoft v01-17-09.
Jet Energy / GeV Jet Energy Resolution [%] Jet Energy Resolution Error [%]
91 3.85394 0.0495277
200 3.10328 0.0397759
360 3.05806 0.0389507
500 3.19743 0.0408553

Reconstruction information used for validation:

  • ilcsoft v01-17-09, but with master branches of PandoraPFA, MarlinPandora and PandoraAnalysis as of 05-08-16 (to go into ilcsoft v01-17-10).
  • 100 ns timing cut in the ECal and HCal.
  • Realistic digitsation in ILDCaloDigi.
  • Semi-infinite hadronic energy truncation.
  • Calibration done using PandoraAnalysis toolkit v01-02-01.
  • Pandora settings default used from master branch of MarlinPandora as of 05-08-16.
Jet Energy / GeV Jet Energy Resolution [%] Jet Energy Resolution Error [%]
91 3.57955 0.0460014
200 2.79755 0.0358571
360 2.67042 0.0340132
500 2.73888 0.0349961