Jet Energy Resolution Validations of Pandora (Master 11 10 16) - PandoraPFA/MarlinPandora GitHub Wiki

Validation of Pandora from 11-10-16


Reconstruction information used for validation:

  • ilcsoft v01-17-10.
  • 100 ns timing cut in the ECal and HCal.
  • Realistic digitsation in ILDCaloDigi.
  • Semi-infinite hadronic energy truncation.
  • Calibration done using PandoraAnalysis toolkit v01-02-01.
  • Pandora settings default used from ilcsoft v01-17-10.
Jet Energy / GeV Jet Energy Resolution [%] Jet Energy Resolution Error [%]
91 3.5783 0.0459854
200 2.7978 0.0358604
360 2.67863 0.0341178
500 2.74494 0.0350735

Reconstruction information used for validation:

  • ilcsoft v01-17-10, but with master branches of PandoraPFA, MarlinPandora and PandoraAnalysis as of 11-10-16
  • 100 ns timing cut in the ECal and HCal.
  • Realistic digitsation in ILDCaloDigi.
  • Semi-infinite hadronic energy truncation.
  • Calibration done using PandoraAnalysis toolkit v01-02-01.
  • Pandora settings default used from master branch of MarlinPandora as of 11-10-16.
Jet Energy / GeV Jet Energy Resolution [%] Jet Energy Resolution Error [%]
91 3.58525 0.0460747
200 2.79831 0.0358669
360 2.74716 0.0349906
500 2.82535 0.036101

Degradation due to the fact that software compensation is only applied to clusters of energy less than 100 GeV as it has only been trained up to this energy.