Jet Energy Resolution Validations of Pandora (Master 11 10 16) - PandoraPFA/MarlinPandora GitHub Wiki
Validation of Pandora from 11-10-16
Reconstruction information used for validation:
- ilcsoft v01-17-10.
- 100 ns timing cut in the ECal and HCal.
- Realistic digitsation in ILDCaloDigi.
- Semi-infinite hadronic energy truncation.
- Calibration done using PandoraAnalysis toolkit v01-02-01.
- Pandora settings default used from ilcsoft v01-17-10.
Jet Energy / GeV | Jet Energy Resolution [%] | Jet Energy Resolution Error [%] |
---|---|---|
91 | 3.5783 | 0.0459854 |
200 | 2.7978 | 0.0358604 |
360 | 2.67863 | 0.0341178 |
500 | 2.74494 | 0.0350735 |
Reconstruction information used for validation:
- ilcsoft v01-17-10, but with master branches of PandoraPFA, MarlinPandora and PandoraAnalysis as of 11-10-16
- 100 ns timing cut in the ECal and HCal.
- Realistic digitsation in ILDCaloDigi.
- Semi-infinite hadronic energy truncation.
- Calibration done using PandoraAnalysis toolkit v01-02-01.
- Pandora settings default used from master branch of MarlinPandora as of 11-10-16.
Jet Energy / GeV | Jet Energy Resolution [%] | Jet Energy Resolution Error [%] |
---|---|---|
91 | 3.58525 | 0.0460747 |
200 | 2.79831 | 0.0358669 |
360 | 2.74716 | 0.0349906 |
500 | 2.82535 | 0.036101 |
Degradation due to the fact that software compensation is only applied to clusters of energy less than 100 GeV as it has only been trained up to this energy.